USSPA / Gebläse / Pumpe / Reparatur
USSPA - Pumpe und Gebläse gehen stündlich für eine Minute an.
mögliche Ursache: Punkt 6 oder Punkt 7 wurden geändert.
After power supply is switched on – everything already set in production
- press and hold the Filter key for 20 seconds (always make sure the original label / overlay is on the keypad, never depress the original rubber buttons on the keypad!!!)
- then set the following using arrows, you can switch between the setting by pressing the Filter key once
- light intensity LI – 1-single intensity / 2-two intensity
- external heating RH – 0-disable / 1-enable
- blower BL – 0-not installed / 1-1 Speed / 2-2 Speeds
- DJS / water level sensor H2O – 0-None / 1-water level sensor / 2-DJS
- Water Level Option LO – 0-Indicate Only / 1-Close Outputs
- filter cycle FC – 1-filter cycle / 2-Purge Cycle
- Filter Pump FP – 0-Pump 1 / 1-Baby Pump
- Heating Pump HP – 0-On Pump 1 / 1-On Baby Pump
- filter cleaning reminder CF – 1-for on / 2-for off